Skip to main content
N2 · PSA nitrogen generator

GNA Nitrogen Generator

Reliable and efficient nitrogen generation for the most demanding requirements.

up to 99.9995%Nitrogen purity (from 95.0%)
5–9 barGNitrogen outlet pressure
PSAPressure swing adsorption
CEcertified (2014/68/EU)

Overview

Advanced PSA technology

GNA nitrogen generators from SCHMIDLIN Labor + Service GmbH & Co. KG provide continuous on-site nitrogen production.

  • Technology: The generators are based on proven Pressure Swing Adsorption (PSA) technology.
  • Operating principle: The system uses two columns filled with an inert carbon molecular sieve (CMS) to effectively separate nitrogen from the other gases in air.
  • Low maintenance: As the entire system contains almost no moving parts, maintenance and repair requirements are minimal.
System layout: compressed air supply with GNA nitrogen generator
System layout of a GNA nitrogen supply.

Control & Safety

Smart control, certified, monitored.

Intelligent control

The control cabinet houses all electrical components, a touchscreen and a PLC that controls all process valves, the condensate drain and the purity sensor.

Certified safety

CE-marked products meet the safety requirements of the EU Pressure Equipment Directive 2014/68/EU and the Low Voltage Directive 2014/35/EU.

Integrated alarm

A low-pressure alarm provides additional operational safety.

Specifications

Technical highlights (models GNA1 to GNA150T)

PropertySpecification
Nitrogen purity95.0% up to high-purity 99.9995%
Nitrogen outlet pressure5 – 9 barG
Voltage / frequency110–240 V / 50–60 Hz
Operating modeContinuous
Ambient temperatureMinimum +5 °C to maximum +50 °C

Installation

Installation and operating conditions

To ensure lasting and stable performance, the following operating conditions must be met:

Ventilation

The room must be well ventilated to maintain the operating temperature and ensure a proper air supply. Exhaust air must be vented to the outside.

Air supply

The feed air must come from a compressor with a refrigeration dryer and filters (pre-filter and micro-filter) to ensure that it is free of moisture and oil.

Air quality

The quality of the feed air must comply with ISO/EN 8573-1:2010 Class 1.4.1.

Dew point & temperature

The air dew point must not exceed +5 °C PDP, and the feed air temperature must not exceed 45 °C.

Contact

Which GNA fits your demand?

Do not hesitate to contact us by email or phone so that we can find the best solution for you. We look forward to hearing from you!